SAS disk reservations provide the ability to connect to the disk redundantly—or even across multiple machines—while ensuring it is only used by one of them at a time. SAS provides many more features than SATA does—including full duplex operations, advanced error recovery, multipath, and disk reservations. It too was an extension on an existing interface bus which offered greatly improved performance. SATA+AHCI improved data transfer speeds, simplicity of communication, and included abilities that we today take for granted, such as “hot swap” and command queueing. These concepts also apply to other operating systems, but the tools might differ slightly.
Below we will discuss exactly how to do this with FreeBSD’s sesutil or the management tools for your HBA. Though a truism, it bears emphasizing that with a little planning, management and maintenance of storage systems can be made easier and safer. The total throughput possible from the connected disks is still limited by the number of lanes available, but this is likely the best approach in systems with more than a dozen disks.
I moved the system dataset to the boot pool. I don’t move any data, no reveryplay apps are running, this is a vanilla Scale install so far, yet the HDD is in constant work. 1 SSD to boot and 1 HDD to store data. Agree, I have used SeaChest with good results for this same issue on scale plus drive cache. If you do it on a live pool, I’d back up your data first.
Connect to a computer or mobile device remotely, whether it’s across town or halfway around the world.
Most Seagate disks have configurable Extended Power Conditions (EPC) settings that include timers for how long the disk needs to stay idle before entering various low-power modes. Disk vendors typically provide their own vendor-specific ways to do persistent configuration of power management settings, so it’s worth trying to use those instead so the desired configuration doesn’t depend on the host system applying it, instead being configured in the drive (but in some cases it might be desirable to have the host configure that!). To prevent parking the heads at all a value greater than 128 may do the job (254 is a common choice, as the highest-power setting available), but it’s possible that some disks won’t behave this way because the ATA specification refers only to spinning down the disk and does not specify anything about parking heads. Typical SAS connectors support up to 4 drives per “lane”, but with an expander up to 255 devices are possible. An eight lane controller can only directly attach to 8 disks, requiring more controllers (consuming additional PCI-E slots) to connect more drives. This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.
I will optimize settings later for the security/quietness tradeoff however, I’m very pleased with it for now. How can I set this value on the Truenas interface? Keeping it spinning but not accessing data is safer. I would still recommend against idling your drive as that reduces longevity. I also set the tunable vfs.zfs.txg.timeout to a somewhat large value so the regular syncs don’t happen every 5 seconds.
This will activate the fault LED for element 9 (Slot 08) on the first SES device. You can avoid any uncertainty by enabling the “locate” or “fault” LED for the drive you mean to replace. This example creates a new GPT partition scheme on da36, creates a 4 GiB swap partition aligned to 1 MiB boundaries, and then adds a ZFS partition with the label e3s01-ZGY0XH87 using the remainder of the space on the disk.
Chrome Remote Desktop
The parking rate basically drops to zero at the time I updated the settings for the Seagate drives, and the Western Digital one hasn’t changed because it needs to be powered off to change that setting and I haven’t done so yet. The other slight annoyance when setting the idle3 timer on WD drives is that changes only take effect when the drive is powered on, usually meaning the host computer must be fully shut down and started back up for any changes to be seen- this makes experimentation to determine how raw timer values are interpreted a slower and more tedious process. Of particular note, WD Green drives ship configured to park the heads after only 8 seconds of inactivity which could notionally wear out the disk in a matter of months if the heads are cycling more-or-less continuously! For drives made by Western Digital, the inactivity timer for parking the heads is called the idle3 timer.
For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime. Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong. Experienced enterprise storage managers also keep extensive notes including the model number, SKU and/or URL for reordering, purchase order information, warranty end date, warranty URL, and any other useful information about each drive. While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.
StarDesk – Remote Desktop & Gaming
If you need more advanced functionality than mpsutil provides, LSI provides their native tools sas2ircu and sas3ircu for FreeBSD. On my system, this command produces a bright red LED lit for that slot, physically highlighting the correct drive to replace. So, to activate the LED for the first disk displayed above, we first need to determine the enclosure handle number (0001), and then the slot number of the disk (03). This partitions each disk and labels the ZFS partition with the enclosure, slot, and serial number of the corresponding disk. As with a number of tools in FreeBSD, sesutil supports outputting JSON via the libxo library.
For chassis with larger numbers of drives, or when connecting external JBOD chassis, it is common for the drives to connect to a specialized board that provides power and routing for the SATA/SAS signals to the controller. When building a storage system, there are many different ways the disks might be connected to the system. NVME-oF allows storage devices and arrays in remote chassis to be connected to local motherboards. NVMe storage comes in many form factors, from small M.2 devices to U.2 and other hot-swappable formats intended for servers. NVMe connects storage devices directly to the PCIe bus, offering extremely low latency and high throughput.
- Although it’s empty, so this is probably not the source of the constant HDD noise.
- In this case, there are at least two disks that I probably need to configure, since /dev/sde seems to be parking as often as about every 4 minutes (0.004 Hz) and /dev/sdc is only parking slightly less often.
- It’s a datacenter drive, very loud, so it’s still audible.
- SAS provides many more features than SATA does—including full duplex operations, advanced error recovery, multipath, and disk reservations.
- Send it to the other user who has the program and they will be able to access and control your device.
- I don’t move any data, no apps are running, this is a vanilla Scale install so far, yet the HDD is in constant work.
It’s hard to imagine why your drives are that loud! It’s a datacenter drive, very loud, so it’s still audible. For quietness, a noise reducing case, move it somewhere else, quieter drives, maybe SSD instead of hard drives, etc.
How to Convert a Recorded AnyDesk Session in 3 Easy Steps
Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
- The map command displays all of the SES devices and each element (this is the nomenclature in SES) connected to them.
- Many backplanes include support for SCSI Enclosure Services (SES).
- It is very popular among professionals who provide technical support.
- Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
- 1 SSD to boot and 1 HDD to store data.
Sounds like the drives being woken for the ZIL to flush writes to the ZFS pool and then going back to idle/sleep every 5 seconds. Enable the checkmark for the Syslog and choose a pool that is not based on hard drives. I had this same problem, using HGST data center refurb drives.
Other interfaces for remote storage include iSCSI, Fiber-Channel, Infiniband, RoCE, and others, but those specialized solutions are beyond the scope of this article. Serial Attached SCSI (SAS) is the most common interface for enterprise storage, first appearing in 2004. Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s. In this article we will discuss some strategies and tools to make managing disk arrays on FreeBSD (and related platforms like TrueNAS Core) much easier. It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use